Download

Home/Download
APN1001 Power Measurement Module Simplified Chinese Version S/W
Apply to :APN1001 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.10.08
Language :Simplified Chinese Version
File Size :2.2MByte
Brief : For APN1001 Series Power Meters only. Read back all measurement data from APN1001, display value, waveforms, harmonics order distribution, record operation etc. The APN1001 parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
APN1001 Power Measurement Module Traditional Chinese Version S/W
Apply to :APN1001 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.10.08
Language :Traditional Chinese Version
File Size :2.2MByte
Brief : For APN1001 Series Power Meters only. Read back all measurement data from APN1001, display value, waveforms, harmonics order distribution, record operation etc. The APN1001 parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
APN1001 Power Measurement Module English Version S/W
Apply to :APN1001 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.10.08
Language :English Version
File Size :2.2MByte
Brief : For APN1001 Series Power Meters only. It read back all measurement data from APN1001, display value, waveforms, harmonics order distribution, record operation etc. The APN1001 parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
APN1211 Power Meter S/W (PowerExplorer For APN1211)
Apply to :APN1211 Series、APN1311 Series、AWE1611 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2013.09.23
Language :English, Simplified & Traditional Chinese
File Size :12.0MByte
Brief : For APN1211 Series, APN1311 Series, AWE1611 Series Power Meters. It read back all measurement data from instruments, display value, waveforms, harmonics order distribution, record operation etc. The instrument parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
APN1311 ATE Power Meter S/W(PowerExplorer For APN1211)
Apply to :APN1211 Series、APN1311 Series、AWE1611 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2013.09.23
Language :English, Simplified & Traditional Chinese
File Size :12.0MByte
Brief : For APN1211 Series, APN1311 Series, AWE1611 Series Power Meters. It read back all measurement data from instruments, display value, waveforms, harmonics order distribution, record operation etc. The instrument parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
AWE1611 Power Analyzer Analyzer S/W(PowerExplorer For APN1211)
Apply to :APN1211 Series、APN1311 Series、AWE1611 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2013.09.23
Language :English, Simplified & Traditional Chinese
File Size :12.0MByte
Brief : For APN1211 Series, APN1311 Series, AWE1611 Series Power Meters. It read back all measurement data from instruments, display value, waveforms, harmonics order distribution, record operation etc. The instrument parameters setting such as sampling rate, communication baudrate and slave instruments addressing could be manipulated with the S/W.
AWE2101 Power Parameter Instrument Simplified Chinese Version S/W
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.04.07
Language :Simplified Chinese Version
File Size :2.2MByte
Brief : For AWE2101 Series Power Meters only. It read back all measurement data from AWE2101 Series, display value, waveforms, harmonics order distribution, record operation etc.
AWE2101 Power Parameter Instrument Traditional Chinese Version S/W
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.04.07
Language :Traditional Chinese Version
File Size :2.2MByte
Brief : For AWE2101 Series Power Meters only. It read back all measurement data from AWE2101 Series, display value, waveforms, harmonics order distribution, record operation etc.
AWE2101 Power Parameter Instrument English Version S/W
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2011.04.07
Language :English Version
File Size :2.6MByte
Brief : For AWE2101 Series Power Meters only. It read back all measurement data from AWE2101 Series, display value, waveforms, harmonics order distribution, record operation etc.
AWE2111 Analyzer S/W(PowerExplorer For AWE2111)
Apply to :AWE2111 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2014.05.10
Language :English, Simplified & Traditional Chinese
File Size :14.0MByte
Brief : This S/W included all Simplified & Traditional Chinese Versions, is for AWE2111 Series Power Meters. It read back all measurement data from AWE2101 Series, display value, waveforms, harmonics order distribution, record operation etc. Recording operation is independent to main S/W. It can change setting parameters of instruments, such as sampling, display and alarm etc.
AWS2103 3 Phase Power Meter Simplified Chinese S/W
Apply to :AWS2103 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2012.05.21
Language :Simplified Chinese Version
File Size :1.6MByte
Brief : For AWS2103 Series 3 phases Power Meters, it can read back all measurement data from AWS2103 Series 3 phases, display value, waveforms, harmonics order distribution, record operation, 3 phases total parameters.
AWS2103 3 Phase Power Meter Traditional Chinese S/W
Apply to :AWS2103 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2012.05.21
Language :Traditional Chinese Version
File Size :1.6MByte
Brief : For AWS2103 Series 3 phases Power Meters, it can read back all measurement data from AWS2103 Series 3 phases, display value, waveforms, harmonics order distribution, record operation, 3 phases total parameters.
AWS2103 3 Phase Power Meter English S/W
Apply to :AWS2103 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2012.05.21
Language :English Version
File Size :1.6MByte
Brief : For AWS2103 Series 3 phases Power Meters, it can read back all measurement data from AWS2103 Series 3 phases, display value, waveforms, harmonics order distribution, record operation, 3 phases total parameters.
APN1001 Power Parameter Measurement Module USB Driver
Apply to :APN1001X-U Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : USB Driver for APN1001X-U Series.
APN1211 Power Meter USB Driver S/W
Apply to :APN1211X-U Series、AWE1611 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : USB Driver for APN1211X-U Series.
AWE1611 Power Meter USB Driver S/W
Apply to :APN1211X-U Series、AWE1611 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : USB Driver for AWE1611 Series, since the S/W for AWE1611 Series are compatible with APN1211, so driver for AWE1611 is also driver for APN1211-U Series.
AWE2101 Series Power Parameter Instruments USB Driver
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : USB Driver for AWE2101 Series.
AWE2111 Series Power Parameter Instruments USB Driver
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief :USB Driver for AWE2111 Series
AWS2103 Series 3 Phases Power Analyzers USB Driver
Apply to :AWE2101 Series
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief :USB Driver for AWS2103 Series 3 Phases Power Analyzers
Modbus-RTU Tuning Utility
Apply to :APN Series, AWE Series, AWS Series All that with Communication
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief :Standard Modbus-RTU protocal tester which show transmit and receive bytes transparently. Coded in DELPHI7 w. SRC.
Floating Point and Inner Codes Conversion Utility
Apply to :NULL
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : FloatBin is utility for S/W and micro controllers developers. The utility convert either single or double precision floating point data to binary, Decimal or hexadecimal codes. It can also reverse the data inner code to floating point for inverse conversion. When binary data input for conversion, it must be exactly 8 bits of 1 byte. More than or less than 8 bits will get an error, the data should be input with 0 and 1. While input a hexadecimal data for conversion, it must be 0-FF. Over 2 digits width or leave it blank will also result to error.
Capacitance and Inductive Resistance Calculator
Apply to :NULL
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief :容抗感抗計算程序,可以根據不同的容量或電感量,不同的頻率算出容抗,感抗或根據容抗或阻抗計算出容量或電感量,原理及其簡單,但也不失爲實用的電子工程小軟件。
Inductance Calculation Utility
Apply to :NULL
OS :Win2000/Win2003/Winxp/Vista/Win7
Compile Date :2015.09.12
Language :NULL
File Size :1.4MByte
Brief : A choke turns caculation utility.